Urology Annals

ORIGINAL ARTICLE
Year
: 2020  |  Volume : 12  |  Issue : 2  |  Page : 122--127

Is plasma sterilization the modality of choice of sterilization today for endourological procedures such as ureterorenoscopy and retrograde intrarenal surgery? A single-center retrospective evaluation of 198 patients


Kandarp Priyakant Parikh, Ravi Jineshkumar Jain, Aditya K Parikh 
 Department of Genito Urinary Surgery, Minimal Access Surgery Training Institute, Shyam Urosurgical Hospital, Ahmedabad, Gujarat, India

Correspondence Address:
Dr. Ravi Jineshkumar Jain
Minimal Access Surgery Training Institute, Shyam Urosurgical Hospital, Viva Complex, 4th Floor, Opposite Parimal Garden, Ellisbridge, Ahmedabad . 380 006, Gujarat
India

Introduction: The prevalence of infective complications among patients undergoing Retrograde Intrarenal Surgery (RIRS) for renal stone is 1.7%-18%, including fever, Systemic Inflammatory Response Syndrome (SIRS) and sepsis. The infectious complications of RIRS can be minimised by strict aseptic precautions and plasma sterilization. The Sterrad Next Generation (Sterrad NX) System, a low-temperature sterilizer represents the next generation of low-temperature hydrogen peroxide gas plasma sterilizers. This study was conducted to evaluate the efficacy of plasma sterilization among patients undergoing ureterorenoscopy (URS) and RIRS. The primary endpoint of this study was incidence of septicemia or related complications. Till date, there is no study on the incidence of infection rate in RIRS in relation to a specific mode of sterilization. Material and Methods: This is a retrospective study comprising of 198 patients undergoing URS and/or RIRS. The parameters studied were incidence of post-operative fever, Systemic Inflammatory Response Syndrome (SIRS), pyelonephritis or septicemic shock. Results: Out of 198 patients, incidence of post-operative fever was 3.5%, SIRS was 1.7%, pyelonephritis was 0.7% and septicemic shock was 0%. This is statistically significantly low septicemia rate among patients undergoing URS and /or RIRS as compared to the available literature. No health hazards of plasma sterilization were noted. No damage to the endoscopes or instruments was noted. Conclusion: Sterrad NX based on hydrogen peroxide gas plasma (HPGP) technology is highly efficacious, safe and the modality for sterilization of instruments, including heat labile instruments such as semi rigid, flexible and chip on the tip endoscopes and other EndoUrology armamentarium.


How to cite this article:
Parikh KP, Jain RJ, Parikh AK. Is plasma sterilization the modality of choice of sterilization today for endourological procedures such as ureterorenoscopy and retrograde intrarenal surgery? A single-center retrospective evaluation of 198 patients.Urol Ann 2020;12:122-127


How to cite this URL:
Parikh KP, Jain RJ, Parikh AK. Is plasma sterilization the modality of choice of sterilization today for endourological procedures such as ureterorenoscopy and retrograde intrarenal surgery? A single-center retrospective evaluation of 198 patients. Urol Ann [serial online] 2020 [cited 2020 Jul 3 ];12:122-127
Available from: http://www.urologyannals.com/article.asp?issn=0974-7796;year=2020;volume=12;issue=2;spage=122;epage=127;aulast=Parikh;type=0